Partima/Pratima  R. Solanki
Partima/Pratima R. Solanki
Verified email at mail.jnu.ac.in
Title
Cited by
Cited by
Year
Nanostructured metal oxide-based biosensors
PR Solanki, A Kaushik, VV Agrawal, BD Malhotra
NPG Asia Materials 3 (1), 17-24, 2011
4542011
Iron oxide nanoparticles–chitosan composite based glucose biosensor
A Kaushik, R Khan, PR Solanki, P Pandey, J Alam, S Ahmad, ...
Biosensors and bioelectronics 24 (4), 676-683, 2008
4362008
Zinc oxide nanoparticles-chitosan composite film for cholesterol biosensor
R Khan, A Kaushik, PR Solanki, AA Ansari, MK Pandey, BD Malhotra
Analytica Chimica Acta 616 (2), 207-213, 2008
2312008
Recent advances in self-assembled monolayers based biomolecular electronic devices
SK Arya, PR Solanki, M Datta, BD Malhotra
Biosensors and Bioelectronics 24 (9), 2810-2817, 2009
2212009
Cholesterol biosensor based on cholesterol esterase, cholesterol oxidase and peroxidase immobilized onto conducting polyaniline films
S Singh, PR Solanki, MK Pandey, BD Malhotra
Sensors and Actuators B: Chemical 115 (1), 534-541, 2006
2042006
Sol–gel derived nanoporous cerium oxide film for application to cholesterol biosensor
AA Ansari, A Kaushik, PR Solanki, BD Malhotra
Electrochemistry Communications 10 (9), 1246-1249, 2008
1962008
Iron oxide-chitosan nanobiocomposite for urea sensor
A Kaushik, PR Solanki, AA Ansari, G Sumana, S Ahmad, BD Malhotra
Sensors and Actuators B: Chemical 138 (2), 572-580, 2009
1852009
Sol-gel derived nanostructured cerium oxide film for glucose sensor
AA Ansari, PR Solanki, BD Malhotra
Applied Physics Letters 92 (26), 263901, 2008
1292008
Covalent immobilization of cholesterol esterase and cholesterol oxidase on polyaniline films for application to cholesterol biosensor
S Singh, PR Solanki, MK Pandey, BD Malhotra
Analytica Chimica Acta 568 (1-2), 126-132, 2006
1292006
Hydrogen peroxide sensor based on horseradish peroxidase immobilized nanostructured cerium oxide film
AA Ansari, PR Solanki, BD Malhotra
Journal of biotechnology 142 (2), 179-184, 2009
1192009
Multi-walled carbon nanotubes/sol–gel-derived silica/chitosan nanobiocomposite for total cholesterol sensor
PR Solanki, A Kaushik, AA Ansari, A Tiwari, BD Malhotra
Sensors and Actuators B: Chemical 137 (2), 727-735, 2009
1192009
Electrophoretically deposited reduced graphene oxide platform for food toxin detection
S Srivastava, V Kumar, MA Ali, PR Solanki, A Srivastava, G Sumana, ...
Nanoscale 5 (7), 3043-3051, 2013
1172013
Antibody immobilized cysteamine functionalized-gold nanoparticles for aflatoxin detection
A Sharma, Z Matharu, G Sumana, PR Solanki, CG Kim, BD Malhotra
Thin Solid Films 519 (3), 1213-1218, 2010
1172010
Chitosan–iron oxide nanobiocomposite based immunosensor for ochratoxin-A
A Kaushik, PR Solanki, AA Ansari, S Ahmad, BD Malhotra
Electrochemistry Communications 10 (9), 1364-1368, 2008
1172008
Cholesterol biosensor based on N-(2-aminoethyl)-3-aminopropyl-trimethoxysilane self-assembled monolayer
SK Arya, AK Prusty, SP Singh, PR Solanki, MK Pandey, M Datta, ...
Analytical Biochemistry 363 (2), 210-218, 2007
1152007
Nanostructured zinc oxide film for urea sensor
A Ali, AA Ansari, A Kaushik, PR Solanki, A Barik, MK Pandey, ...
Materials Letters 63 (28), 2473-2475, 2009
1002009
Nanostructured zinc oxide platform for cholesterol sensor
PR Solanki, A Kaushik, AA Ansari, BD Malhotra
Applied Physics Letters 94 (14), 143901, 2009
1002009
Zinc oxide-chitosan nanobiocomposite for urea sensor
PR Solanki, A Kaushik, AA Ansari, G Sumana, BD Malhotra
Applied Physics Letters 93 (16), 163903, 2008
952008
Nanostructured zinc oxide platform for mycotoxin detection
AA Ansari, A Kaushik, PR Solanki, BD Malhotra
Bioelectrochemistry 77 (2), 75-81, 2010
942010
Application of octadecanethiol self-assembled monolayer to cholesterol biosensor based on surface plasmon resonance technique
SK Arya, PR Solanki, RP Singh, MK Pandey, M Datta, BD Malhotra
Talanta 69 (4), 918-926, 2006
922006
The system can't perform the operation now. Try again later.
Articles 1–20