In vivo continuous and simultaneous monitoring of brain energy substrates with a multiplex amperometric enzyme-based biosensor device CA Cordeiro, MG de Vries, W Ngabi, PE Oomen, T Cremers, ... Biosensors and Bioelectronics 67, 677-686, 2015 | 55 | 2015 |
The role of surface availability in membrane-induced selectivity for amperometric enzyme-based biosensors CA Cordeiro, MG De Vries, T Cremers, BHC Westerink Sensors and Actuators B: Chemical 223, 679-688, 2016 | 46 | 2016 |
Microdialysis-coupled enzymatic microreactor for in vivo glucose monitoring in rats BU Moon, MG de Vries, CA Cordeiro, BHC Westerink, E Verpoorte Analytical chemistry 85 (22), 10949-10955, 2013 | 34 | 2013 |
In vivo “real-time” monitoring of glucose in the brain with an amperometric enzyme-based biosensor based on gold coated tungsten (W-Au) microelectrodes CA Cordeiro, A Sias, T Koster, BHC Westerink, T Cremers Sensors and Actuators B: Chemical 263, 605-613, 2018 | 30 | 2018 |
Effects of a vigilance enhancing drug, modafinil, on rat brain cortex amino acids: a microdialysis study C Pierard, D Lagarde, B Barrere, P Duret, C Cordeiro, CY Guezennec, ... Medical science research 25 (1), 51-54, 1997 | 16 | 1997 |
In vivo real-time monitoring of corticostriatal synaptic plasticity CA Cordeiro, T Koster, L Kuhl, J Folgering, T Cremers European Neuropsychopharmacology 27, S603-S604, 2017 | | 2017 |
In vivo real-time brain biomonitoring with gold-coated tungsten (W-Au) based microbiosensors C Cordeiro, G Flik, T Cremers, BHC Westerink European Neuropsychopharmacology 2 (26), S364, 2016 | | 2016 |
Calibration in vivo des sondes de microdialyse pour le dosage des acides amines extra-cellulaires du cortex cerebral de rat C Pierard, B Barrere, C Cordeiro, L Brachais, CY Guezennec, M Peres TRAVAUX SCIENTIFIQUES-CHERCHEURS DU SERVICE DE SANTE DES ARMEES 17, 263-264, 1996 | | 1996 |
Detection et quantification des acides amines neurotransmetteurs dans les microdialysats de cerveau de rat C Pierard, B Barrere, C Cordeiro, PJ Douce, CY Guezennec, M Peres TRAVAUX SCIENTIFIQUES-CHERCHEURS DU SERVICE DE SANTE DES ARMEES 17, 259-260, 1996 | | 1996 |
P. 1. l. 017 In vivo real-time brain biomonitoring with gold-coated tungsten (W-Au) based microbiosensors C Cordeiro, G Flik, T Cremers, BHC Westerink Biosensors and Bioelectronics 33, 260-266, 0 | | |
Surface availability, modulated by the choice of permselective membranes, regulates the performance of amperometric enzyme-based biosensors. CA Cordeiro, MG de Vries, T Cremers, BHC Westerink | | |
APPLICATION OF AN ENZYMATIC MICROREACTOR COUPLED WITH MICRODIALYSIS FOR CONTINUOUS MONITORING OF SUBCUTANEOUS GLUCOSE IN RATS BU Moon, MG de Vries, CA Cordeiro, AJM Schoonen, BHC Westerink, ... | | |
Electrochemical biosensors for in vivo glucose biomonitoring (and beyond?) CA Cordeiro, MG de Vries, T Cremers, BHC Westerink | | |
The impact of sterilization on the performance of an implantable enzyme-based glucose biosensor. CA Cordeiro, MG de Vries, T Cremers, BHC Westerink | | |
A wireless implantable microbiosensor device for continuous glucose monitoring (CGM). CA Cordeiro, MG de Vries, W BHC, T Cremers | | |