עקוב אחר
Fred van Nijnatten
Fred van Nijnatten
Philips Healthcare
כתובת אימייל מאומתת בדומיין philips.com
כותרת
צוטט על ידי
צוטט על ידי
שנה
Quantification of arterial flow using digital subtraction angiography
O Bonnefous, VM Pereira, R Ouared, O Brina, H Aerts, R Hermans, ...
Medical physics 39 (10), 6264-6275, 2012
842012
Quantification of internal carotid artery flow with digital subtraction angiography: validation of an optical flow approach with Doppler ultrasound
VM Pereira, R Ouared, O Brina, O Bonnefous, J Satwiaski, H Aerts, ...
American Journal of Neuroradiology 35 (1), 156-163, 2014
502014
Flat-panel detector CT assessment in stroke to reduce times to intra-arterial treatment: a study of multiphase computed tomography angiography in the angiography suite to …
M Bouslama, DC Haussen, JA Grossberg, CM Barreira, IMJ Bom, ...
International Journal of Stroke 16 (1), 63-72, 2021
282021
Intra-aneurysmal flow patterns: illustrative comparison among digital subtraction angiography, optical flow, and computational fluid dynamics
O Brina, R Ouared, O Bonnefous, F van Nijnatten, P Bouillot, P Bijlenga, ...
American Journal of Neuroradiology 35 (12), 2348-2353, 2014
282014
Understanding angiography-based aneurysm flow fields through comparison with computational fluid dynamics
JR Cebral, F Mut, BJ Chung, L Spelle, J Moret, F Van Nijnatten, D Ruijters
American Journal of Neuroradiology 38 (6), 1180-1186, 2017
192017
Novel flat-panel cone-beam CT compared to multi-detector CT for assessment of acute ischemic stroke: a prospective study
P Nicholson, NM Cancelliere, J Bracken, E Hummel, F van Nijnatten, ...
European Journal of Radiology 138, 109645, 2021
172021
Performance characterization of a prototype dual‐layer cone‐beam computed tomography system
F Ståhl, D Schäfer, A Omar, P van de Haar, F van Nijnatten, P Withagen, ...
Medical Physics 48 (11), 6740-6754, 2021
162021
X-ray controlled contrast agent injection
FSB Van Nijnatten
US Patent 10,820,872, 2020
152020
The traveling salesman problem under squared Euclidean distances
M De Berg, F Van Nijnatten, R Sitters, GJ Woeginger, A Wolff
arXiv preprint arXiv:1001.0236, 2010
142010
Range assignment with directional antennas
F van Nijnatten
Master's Thesis. Technische Universiteit Eindhoven, 2008
122008
The butterfly effect: improving brain cone-beam CT image artifacts for stroke assessment using a novel dual-axis trajectory
NM Cancelliere, E Hummel, F van Nijnatten, P van de Haar, P Withagen, ...
Journal of neurointerventional surgery 15 (3), 283-287, 2023
72023
Motion artifact correction for cone beam CT stroke imaging: a prospective series
NM Cancelliere, F van Nijnatten, E Hummel, P Withagen, P van de Haar, ...
Journal of neurointerventional surgery 15 (e2), e223-e228, 2023
42023
O-005 New cone beam CT assessment of acute stroke patients: are we ready for prime time?
N Cancelliere, T Grunhagen, J Bracken, F Nijnatten, T Krings, VM Pereira
Journal of NeuroInterventional Surgery 10 (Suppl 2), A6-A7, 2018
32018
Rectangular cartograms: the game
M de Berg, F van Nijnatten, B Speckmann, K Verbeek
Proceedings of the twenty-fifth annual symposium on Computational geometry …, 2009
32009
E-081 assessment of the MAFA ratio as a quantitative prognostic marker of aneurysm occlusion after flow diverter treatment
VM Pereira, O Brina, J Bracken, T Krings, K Lovblad, F van Nijnatten, ...
Journal of NeuroInterventional Surgery 8 (Suppl 1), A84-A85, 2016
22016
How to perform DSA-based Cerebral Aneurysm Flow measurements
D Ruijters, N Benachour, T Grünhagen, F van Nijnatten, O Bonnefous, ...
European Society of Radiology 20, 2016
22016
Comparison of cerebral aneurysm flow fields obtained from CFD and DSA
JR Cebral, BJ Chung, F Mut, F van Nijnatten, D Ruijters
Proceedings of Summer Biomechanics, Bioengineering and Biotransport Conference, 2016
22016
Mean aneurysm flow amplitude ratio comparison between DSA and CFD
F van Nijnatten, O Bonnefous, HG Morales, T Grünhagen, R Hermans, ...
Medical Image Computing and Computer-Assisted Intervention--MICCAI 2015 …, 2015
22015
X-ray imaging systems for reducing artefacts associated with anti-scatter grids and methods of operating the same
N Singh, KJ Engel, JWM Jacobs, B Menser, LD Miller, FSB Van Nijnatten
US Patent 11,864,932, 2024
2024
E-160 Detailed evaluation of brain cone-beam CT imaging artifacts: a prospective stroke series
N Cancelliere, E Hummel, F van Nijnatten, P Nicholson, M van Vlimmeren, ...
Journal of NeuroInterventional Surgery 14 (Suppl 1), A163-A163, 2022
2022
המערכת אינה יכולה לבצע את הפעולה כעת. נסה שוב מאוחר יותר.
מאמרים 1–20