Follow
Anjali Sharma
Anjali Sharma
Atma Ram Sanatan Dharma College, University of Delhi
Verified email at arsd.du.ac.in
Title
Cited by
Cited by
Year
Pooled analysis of the accuracy of five cervical cancer screening tests assessed in eleven studies in Africa and India
M Arbyn, R Sankaranarayanan, R Muwonge, N Keita, A Dolo, ...
International journal of cancer 123 (1), 153-160, 2008
4012008
Carbon monoxide (CO) optical gas sensor based on ZnO thin films
A Paliwal, A Sharma, M Tomar, V Gupta
Sensors and Actuators B: Chemical 250, 679-685, 2017
1952017
SnO2 thin film sensor with enhanced response for NO2 gas at lower temperatures
A Sharma, M Tomar, V Gupta
Sensors and Actuators B: Chemical 156 (2), 743-752, 2011
1912011
Metal oxide catalyst assisted SnO2 thin film based SO2 gas sensor
P Tyagi, A Sharma, M Tomar, V Gupta
Sensors and Actuators B: Chemical 224, 282-289, 2016
1532016
A comparative study of RGO-SnO2 and MWCNT-SnO2 nanocomposites based SO2 gas sensors
P Tyagi, A Sharma, M Tomar, V Gupta
Sensors and Actuators B: Chemical 248, 980-986, 2017
1292017
Room temperature trace level detection of NO 2 gas using SnO 2 modified carbon nanotubes based sensor
A Sharma, M Tomar, V Gupta
Journal of Materials Chemistry 22 (44), 23608-23616, 2012
1292012
Metal clusters activated SnO2 thin film for low level detection of NH3 gas
M Shahabuddin, A Sharma, J Kumar, M Tomar, A Umar, V Gupta
Sensors and Actuators B: Chemical 194, 410-418, 2014
1152014
Enhanced response characteristics of SnO2 thin film based NO2 gas sensor integrated with nanoscaled metal oxide clusters
A Sharma, M Tomar, V Gupta
Sensors and Actuators B: Chemical 181, 735-742, 2013
1122013
Effects on the bifurcation and chaos in forced Duffing oscillator due to nonlinear damping
A Sharma, V Patidar, G Purohit, KK Sud
Communications in Nonlinear Science and Numerical Simulation 17 (6), 2254-2269, 2012
1102012
Accuracy of conventional cytology: results from a multicentre screening study in India
R Sankaranarayanan, S Thara, A Sharma, C Roy, S Shastri, C Mahe, ...
Journal of medical screening 11 (2), 77-84, 2004
1082004
Natural history and risk factors in fulminant hepatic failure
U Poddar, BR Thapa, A Prasad, AK Sharma, K Singh
Archives of disease in childhood 87 (1), 54-56, 2002
1052002
Experimental investigations on NO 2 sensing of pure ZnO and PANI–ZnO composite thin films
RK Sonker, BC Yadav, A Sharma, M Tomar, V Gupta
RSC advances 6 (61), 56149-56158, 2016
872016
WO3 nanoclusters–SnO2 film gas sensor heterostructure with enhanced response for NO2
A Sharma, M Tomar, V Gupta
Sensors and Actuators B: Chemical 176, 675-684, 2013
852013
Low temperature operating SnO2 thin film sensor loaded with WO3 micro-discs with enhanced response for NO2 gas
A Sharma, M Tomar, V Gupta
Sensors and Actuators B: Chemical 161 (1), 1114-1118, 2012
722012
Room temperature detection of NO2 gas using optical sensor based on surface plasmon resonance technique
A Paliwal, A Sharma, M Tomar, V Gupta
Sensors and Actuators B: Chemical 216, 497-503, 2015
702015
Optical properties of WO3 thin films using surface plasmon resonance technique
A Paliwal, A Sharma, M Tomar, V Gupta
Journal of Applied Physics 115 (4), 2014
662014
A low temperature operated NO2 gas sensor based on TeO2/SnO2 p–n heterointerface
A Sharma, M Tomar, V Gupta
Sensors and Actuators B: Chemical 176, 875-883, 2013
652013
Low temperature sensing of NO2 gas using SnO2-ZnO nanocomposite sensor
RK Sonker, A Sharma, M Shahabuddin, M Tomar, V Gupta
Adv. Mat. Lett 4 (3), 196-201, 2013
582013
SnO2 thin film sensor having NiO catalyst for detection of SO2 gas with improved response characteristics
P Tyagi, A Sharma, M Tomar, V Gupta
Sensors and Actuators B: Chemical 248, 998-1005, 2017
482017
High performance UV photodetector based on MoS2 layers grown by pulsed laser deposition technique
S Kumar, A Sharma, YT Ho, A Pandey, M Tomar, AK Kapoor, EY Chang, ...
Journal of Alloys and Compounds 835, 155222, 2020
452020
The system can't perform the operation now. Try again later.
Articles 1–20