Clinical implementation of artificial intelligence-driven cone-beam computed tomography-guided online adaptive radiotherapy in the pelvic region P Sibolt, LM Andersson, L Calmels, D Sjöström, U Bjelkengren, ... Physics and imaging in radiation oncology 17, 1-7, 2021 | 142 | 2021 |
Implementing RapidArc into clinical routine: a comprehensive program from machine QA to TPS validation and patient QA A Van Esch, D P. Huyskens, CF Behrens, E Samsøe, M Sjölin, ... Medical physics 38 (9), 5146-5166, 2011 | 107 | 2011 |
Surface guided radiotherapy (SGRT) improves breast cancer patient setup accuracy M Kügele, A Mannerberg, S Nørring Bekke, S Alkner, L Berg, F Mahmood, ... Journal of applied clinical medical physics 20 (9), 61-68, 2019 | 85 | 2019 |
A beam-matching concept for medical linear accelerators D Sjöström, U Bjelkengren, W Ottosson, CF Behrens Acta oncologica 48 (2), 192-200, 2009 | 75 | 2009 |
The feasibility of using Pareto fronts for comparison of treatment planning systems and delivery techniques RO Ottosson, PE Engström, D Sjöström, CF Behrens, A Karlsson, T Knöös, ... Acta oncologica 48 (2), 233-237, 2009 | 67 | 2009 |
Dosimetric characterization of the Exradin W1 plastic scintillator detector through comparison with an in-house developed scintillator system AR Beierholm, CF Behrens, CE Andersen Radiation measurements 69, 50-56, 2014 | 63 | 2014 |
Variability in prostate and seminal vesicle delineations defined on magnetic resonance images, a multi-observer,-center and-sequence study T Nyholm, J Jonsson, K Söderström, P Bergström, A Carlberg, G Frykholm, ... Radiation oncology 8, 1-12, 2013 | 55 | 2013 |
Pareto front analysis of 6 and 15 MV dynamic IMRT for lung cancer using pencil beam, AAA and Monte Carlo RO Ottosson, A Karlsson, CF Behrens Physics in Medicine & Biology 55 (16), 4521, 2010 | 48 | 2010 |
Characterizing a pulse-resolved dosimetry system for complex radiotherapy beams using organic scintillators AR Beierholm, RO Ottosson, LR Lindvold, CF Behrens, CE Andersen Physics in Medicine & Biology 56 (10), 3033, 2011 | 45 | 2011 |
Dose build-up behind air cavities for Co-60, 4, 6 and 8 MV. Measurements and Monte Carlo simulations CF Behrens Physics in Medicine & Biology 51 (22), 5937, 2006 | 45 | 2006 |
Randomized phase II study of nivolumab with or without ipilimumab combined with stereotactic body radiotherapy for refractory metastatic pancreatic cancer (CheckPAC) IM Chen, JS Johansen, S Theile, JX Hjaltelin, SI Novitski, S Brunak, ... Journal of Clinical Oncology 40 (27), 3180-3189, 2022 | 42 | 2022 |
Online adaptive radiotherapy of urinary bladder cancer with full re-optimization to the anatomy of the day: Initial experience and dosimetric benefits LM Åström, CP Behrens, L Calmels, D Sjöström, P Geertsen, ... Radiotherapy and Oncology 171, 37-42, 2022 | 41 | 2022 |
Evaluation of setup accuracy for NSCLC patients; studying the impact of different types of cone-beam CT matches based on whole thorax, columna vertebralis, and GTV W Ottosson, M Baker, M Hedman, CF Behrens, D Sjöström Acta oncologica 49 (7), 1184-1191, 2010 | 36 | 2010 |
Determining intrafractional prostate motion using four dimensional ultrasound system M Baker, CF Behrens BMC cancer 16, 1-7, 2016 | 31 | 2016 |
Dosimetric and geometric evaluation of the use of deformable image registration in adaptive intensity-modulated radiotherapy for head-and-neck cancer RB Eiland, C Maare, D Sjöström, E Samsøe, CF Behrens Journal of radiation research 55 (5), 1002-1008, 2014 | 28 | 2014 |
Clinical evaluation of 3D/3D MRI-CBCT automatching on brain tumors for online patient setup verification–A step towards MRI-based treatment planning SK Buhl, AK Duun-Christensen, BH Kristensen, CF Behrens Acta Oncologica 49 (7), 1085-1091, 2010 | 26 | 2010 |
Towards ultrasound‐guided adaptive radiotherapy for cervical cancer: Evaluation of Elekta's semiautomated uterine segmentation method on 3D ultrasound images SA Mason, TP O’Shea, IM White, S Lalondrelle, K Downey, M Baker, ... Medical Physics 44 (7), 3630-3638, 2017 | 24 | 2017 |
The advantage of deep-inspiration breath-hold and cone-beam CT based soft-tissue registration for locally advanced lung cancer radiotherapy W Ottosson, F Rahma, D Sjöström, CF Behrens, P Sibolt Radiotherapy and Oncology 119 (3), 432-437, 2016 | 23 | 2016 |
Comment on “Characterization of the Exradin W1 scintillator for use in radiotherapy” [Med. Phys. 42, 297–304 (2015)] AR Beierholm, CF Behrens, CE Andersen Medical physics 42 (7), 4414-4416, 2015 | 21 | 2015 |
CTC-ask: a new algorithm for conversion of CT numbers to tissue parameters for Monte Carlo dose calculations applying DICOM RS knowledge RO Ottosson, CF Behrens Physics in Medicine & Biology 56 (22), N263, 2011 | 21 | 2011 |