Follow
Hongdi Li
Hongdi Li
UIH America, Inc
Verified email at united-imaging.com
Title
Cited by
Cited by
Year
First human imaging studies with the EXPLORER total-body PET scanner
RD Badawi, H Shi, P Hu, S Chen, T Xu, PM Price, Y Ding, BA Spencer, ...
Journal of Nuclear Medicine 60 (3), 299-303, 2019
5852019
Performance evaluation of the uEXPLORER total-body PET/CT scanner based on NEMA NU 2-2018 with additional tests to characterize PET scanners with a long axial field of view
BA Spencer, E Berg, JP Schmall, N Omidvari, EK Leung, YG Abdelhafez, ...
Journal of Nuclear Medicine 62 (6), 861-870, 2021
2382021
Total-body dynamic reconstruction and parametric imaging on the uEXPLORER
X Zhang, Z Xie, E Berg, MS Judenhofer, W Liu, T Xu, Y Ding, Y Lv, Y Dong, ...
Journal of Nuclear Medicine 61 (2), 285-291, 2020
1582020
Pet camera with individually rotatable detector modules and/or individually movable shielding sections
WH Wong, J Uribe, H Baghaei, H Li
US Patent 6,744,053, 2004
942004
Total-body quantitative parametric imaging of early kinetics of 18F-FDG
T Feng, Y Zhao, H Shi, H Li, X Zhang, G Wang, PM Price, RD Badawi, ...
Journal of Nuclear Medicine 62 (5), 738-744, 2021
622021
Method and apparatus to prevent signal pile-up
WH Wong, H Li, J Uribe, H Baghaei
US Patent 6,936,822, 2005
542005
Feasibility of a high-speed gamma-camera design using the high-yield-pileup-event-recovery method
WH Wong, H Li, J Uribe, H Baghaei, Y Wang, S Yokoyama
Journal of Nuclear Medicine 42 (4), 624-632, 2001
532001
Basic imaging performance characteristics of a variable field of view PET camera using quadrant sharing detector design
J Uribe, H Baghaei, H Li, S Yokoyama, N Zhang, J Wang, FR Dobbs, ...
IEEE Transactions on Nuclear Science 46 (3), 491-497, 1999
521999
Nuclear science symposium conference record
WH Wong, Y Zhang, S Liu, H Li, H Baghaei, R Ramirez, J Liu
NSS 7, 4117-4122, 0
51
A pentagon photomultiplier-quadrant-sharing BGO detector for a rodent research PET (RRPET)
S Xie, R Ramirez, Y Liu, T Xing, J Uribe, H Li, Y Wang, H Baghaei, S Kim, ...
IEEE transactions on nuclear science 52 (1), 210-216, 2005
442005
The engineering and initial results of a transformable low-cost high-resolution PET camera
H Li, WH Wong, H Baghaei, J Uribe, Y Wang, Y Zhang, S Kim, R Ramirez, ...
IEEE Transactions on Nuclear Science 54 (5), 1583-1588, 2007
412007
A new pileup-prevention front-end electronic design for high resolution PET and gamma camera
H Li, WH Wong, J Uribe, H Baghaei, Y Liu, Y Wang, T Xing, M Aykac
2001 IEEE Nuclear Science Symposium Conference Record (Cat. No. 01CH37310) 4 …, 2001
412001
Method and apparatus to prevent signal pile-up
WH Wong, H Li
US Patent 6,525,322, 2003
392003
A high count rate position decoding and energy measuring method for nuclear cameras using Anger logic detectors
WH Wong, H Li, J Uribe
IEEE Transactions on nuclear science 45 (3), 1122-1127, 1998
391998
Whole-body parametric imaging of 18F-FDG PET using uEXPLORER with reduced scanning time
Y Wu, T Feng, Y Zhao, T Xu, F Fu, Z Huang, N Meng, H Li, F Shao, ...
Journal of Nuclear Medicine 63 (4), 622-628, 2022
372022
Self-gating: an adaptive center-of-mass approach for respiratory gating in PET
T Feng, J Wang, Y Sun, W Zhu, Y Dong, H Li
IEEE transactions on medical imaging 37 (5), 1140-1148, 2017
362017
High-resolution L (Y) SO detectors using PMT-quadrant-sharing for human and animal PET cameras
RA Ramirez, S Liu, J Liu, Y Zhang, S Kim, H Baghaei, H Li, Y Wang, ...
IEEE transactions on nuclear science 55 (3), 862-869, 2008
352008
The design of a high-resolution transformable wholebody PET camera
WH Wong, J Uribe, H Li, H Baghaei, Y Wang, M Aykac, Y Liu, T Xing, ...
IEEE Transactions on Nuclear Science 49 (5), 2079-2084, 2002
332002
Engineering and performance (NEMA and animal) of a lower-cost higher-resolution animal PET/CT scanner using photomultiplier-quadrant-sharing detectors
WH Wong, H Li, H Baghaei, Y Zhang, RA Ramirez, S Liu, C Wang, S An
Journal of Nuclear Medicine 53 (11), 1786-1793, 2012
312012
An efficient detector production method for position-sensitive scintillation detector arrays with 98% detector packing fraction
J Uribe, WH Wong, H Baghaei, R Farrell, H Li, M Aykac, D Bilgen, Y Liu, ...
IEEE Transactions on Nuclear Science 50 (5), 1469-1476, 2003
312003
The system can't perform the operation now. Try again later.
Articles 1–20