A review on amperometric-type immunosensors based on screen-printed electrodes KK Mistry, K Layek, A Mahapatra, C RoyChaudhuri, H Saha Analyst 139 (10), 2289-2311, 2014 | 135 | 2014 |
Study of electrical characteristics of porous alumina sensors for detection of low moisture in gases S Basu, S Chatterjee, M Saha, S Bandyopadhay, KK Mistry, K Sengupta Sensors and Actuators B: Chemical 79 (2-3), 182-186, 2001 | 76 | 2001 |
Development of screen-printed electrode based immunosensor for the detection of HER2 antigen in human serum samples SD Tallapragada, K Layek, R Mukherjee, KK Mistry, M Ghosh Bioelectrochemistry 118, 25-30, 2017 | 55 | 2017 |
Magnesium chromate–TiO2 spinel tape cast thick film as humidity sensor D Saha, R Giri, KK Mistry, K Sengupta Sensors and Actuators B: Chemical 107 (1), 323-331, 2005 | 54 | 2005 |
Design of an SOI-MEMS high resolution capacitive type single axis accelerometer KK Mistry, KBM Swamy, S Sen Microsystem technologies 16, 2057-2066, 2010 | 43 | 2010 |
Sol–gel processed Al2O3 thick film template as sensitive capacitive trace moisture sensor KK Mistry, D Saha, K Sengupta Sensors and Actuators B: Chemical 106 (1), 258-262, 2005 | 43 | 2005 |
Dependence of moisture absorption property on sol–gel process of transparent nano-structured γ-Al2O3 ceramics D Saha, KK Mistry, R Giri, A Guha, K Sensgupta Sensors and Actuators B: Chemical 109 (2), 363-366, 2005 | 35 | 2005 |
Electrochemical characterization of some commercial screen-printed electrodes in different redox substrates KK Mistry, T Sagarika Deepthy, CR Chaudhuri, H Saha Current science, 1427-1436, 2015 | 29 | 2015 |
Design and simulation of a thermo transfer type MEMS based micro flow sensor for arterial blood flow measurement KK Mistry, A Mahapatra Microsystem technologies 18, 683-692, 2012 | 28 | 2012 |
Porous ceramic sensor for measurement of gas moisture in the ppm range S Basu, M Saha, S Chatterjee, KK Mistry, S Bandyopadhay, K Sengupta Materials Letters 49 (1), 29-33, 2001 | 28 | 2001 |
Sensors Actuators D Saha, KK Mistry, R Giri, A Guha, K Sensgupta B 109, 363, 2005 | 26 | 2005 |
Measurement of gas moisture in the ppm range using porous silicon and porous alumina sensors T Islam, KK Mistry, K Sengupta, H Saha Sensors and Materials 16 (7), 345-356, 2004 | 26 | 2004 |
Humidity sensor using porous tape cast alumina substrate S Chatterjee, S Basu, D Chattopadhyay, KK Mistry, K Sengupta Review of Scientific Instruments 72 (6), 2792-2795, 2001 | 25 | 2001 |
Design and development of an amperometric immunosensor based on screen-printed electrodes KK Mistry, K Layek, TN Chell, CR Chaudhuri, H Saha Analytical methods 8 (15), 3096-3101, 2016 | 17 | 2016 |
A Study of Optimization of Various Parameters in the Fabrication of Screen-Printed Electrodes K Layek, Nagahanumaiah, KK Mistry IEEE Sensors Journal 18 (19), 7917-7923, 2018 | 7 | 2018 |
A comparative study in electrochemical response of some commercial screen–printed electrodes (SPEs) KK Mistry, S Kashyup, C RoyChaudhuri, H Saha Sensor Letters 12 (12), 1750-1759, 2014 | 4 | 2014 |
Fabrication of Mesoporous Gamma-Alumina Film by sol-gel and gel casting processes for making moisture sensors KK Mistry Sensors and Transducers 78 (4), 1114-1121, 2007 | 3 | 2007 |
Sensitivity and selectivity of porous tape cast material for gas moisture sensing KK Mistry, S Basu, S Chatterjee, M Saha, D Chattopadhyaya, K Sengupta Journal of Porous Media 6 (4), 2003 | 2 | 2003 |
A-Site Modulation of Co–Ir Based Double Perovskite Oxides (A2CoIrO6, A = Sr, Nd, Pr, and Sm) for Maximization of Water Oxidation and Hybrid Electrolysis … S Ganguly, R Datta, P Basera, SK De, KK Mistry, C Loha, S Ghosh ACS Sustainable Chemistry & Engineering 12 (2), 849-859, 2023 | 1 | 2023 |
Screen printed electrode based sensor for biological and chemical species detection KK Mistry Printed and Flexible Sensor Technology: Fabrication and applications, 12-1-12-28, 2021 | | 2021 |