George S. Wilson
George S. Wilson
Univerity of Kansas
Verified email at ku.edu
Title
Cited by
Cited by
Year
Biosensors: fundamentals and applications
A Turner, I Karube, GS Wilson
Oxford university press, 1987
17781987
Electrochemical biosensors: recommended definitions and classification
DR Thévenot, K Toth, RA Durst, GS Wilson
Biosensors and bioelectronics 16 (1-2), 121-131, 2001
16372001
Implantable glucose sensor
GS Wilson, DS Bindra, BS Hill, DR Thevenot, R Sternberg, G Reach, ...
US Patent 5,165,407, 1992
13251992
Rotating ring-disk enzyme electrode for biocatalysis kinetic studies and characterization of the immobilized enzyme layer
RA Kamin, GS Wilson
Analytical Chemistry 52 (8), 1198-1205, 1980
12581980
Encyclopedia of Electrochemistry of the Elements
AJ Bard, JAA Ketelaar
Journal of The Electrochemical Society 121 (6), 212C, 1974
9621974
Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring
DS Bindra, Y Zhang, GS Wilson, R Sternberg, DR Thevenot, D Moatti, ...
Analytical chemistry 63 (17), 1692-1696, 1991
7911991
Electrochemical biosensors: recommended definitions and classification
DR Thevenot, K Toth, RA Durst, GS Wilson
Pure and applied chemistry 71 (12), 2333-2348, 1999
7721999
Biosensors for real-time in vivo measurements
GS Wilson, R Gifford
Biosensors and Bioelectronics 20 (12), 2388-2403, 2005
7592005
Study and development of multilayer needle-type enzyme-based glucose microsensors
R Sternberg, MB Barrau, L Gangiotti, DR Thévenot, DS Bindra, GS Wilson, ...
Biosensors 4 (1), 27-40, 1989
6931989
Can continuous glucose monitoring be used for the treatment of diabetes
G Reach, GS Wilson
Analytical chemistry 64 (6), 381A-386A, 1992
6791992
Progress toward the development of an implantable sensor for glucose
GS Wilson, Y Zhang, G Reach, D Moatti-Sirat, V Poitout, DR Thévenot, ...
Clinical Chemistry 38 (9), 1613-1617, 1992
6341992
A glucose monitoring system for on line estimation in man of blood glucose concentration using a miniaturized glucose sensor implanted in the subcutaneous tissue and a wearable …
V Poitout, D Moatti-Sirat, G Reach, Y Zhang, GS Wilson, F Lemonnier, ...
Diabetologia 36 (7), 658-663, 1993
6131993
Measurement of pH. Definition, standards, and procedures (IUPAC Recommendations 2002)
RP Buck, S Rondinini, AK Covington, FGK Baucke, CMA Brett, ...
Pure and applied chemistry 74 (11), 2169-2200, 2002
5592002
Recent developments in faradaic bioelectrochemistry
FA Armstrong, GS Wilson
Electrochimica Acta 45 (15-16), 2623-2645, 2000
5502000
Enzyme-based biosensors for in vivo measurements
GS Wilson, Y Hu
Chemical Reviews 100 (7), 2693-2704, 2000
5312000
Towards continuous glucose monitoring: in vivo evaluation of a miniaturized glucose sensor implanted for several days in rat subcutaneous tissue
D Moatti-Sirat, F Capron, V Poitout, G Reach, DS Bindra, Y Zhang, ...
Diabetologia 35 (3), 224-230, 1992
4401992
Elimination of the acetaminophen interference in an implantable glucose sensor
Y Zhang, Y Hu, GS Wilson, D Moatti-Sirat, V Poitout, G Reach
Analytical Chemistry 66 (7), 1183-1188, 1994
4151994
Surface-modified electrochemical detector for liquid chromatography
G Sittampalam, GS Wilson
Analytical Chemistry 55 (9), 1608-1610, 1983
3721983
In vitro and in vivo evaluation in dogs of a miniaturized glucose sensor.
V Poitout, D Moatti, G Velho, G Reach, R Sternberg, DR Thévenot, ...
Asaio Transactions 37 (3), M298-300, 1991
3251991
A temporary local energy pool coupled to neuronal activity: fluctuations of extracellular lactate levels in rat brain monitored with rapid‐response enzyme‐based sensor
Y Hu, GS Wilson
Journal of neurochemistry 69 (4), 1484-1490, 1997
3231997
The system can't perform the operation now. Try again later.
Articles 1–20